SERIES DETAILS
KIOSK Series
Distribution pedestals terminals for campsites, public areas and marinas

CATALOGUE: PRODUCTS SUB-DIVISIONS
All products sub-divisions
TECHNICAL CHARACTERISTICS
- Power supply terminal board: Upon request
- Water service: Upon request
- Circuit breakers: Supplied 6A (other sizes upon request)
THE "SAFE-IN" SAFETY DEVICE
The “SAFE-IN” safety device assembled on the 16A industrial
sockets is the most innovative element of the new OPTIMA
Series.
The “SAFE-IN” device works like the protection installed on
household sockets, i.e., by means of an appropriate shutter, it
closes the input of the socket contact tubes and prevents
accidental and voluntary contact of live parts of the socket with
slim objects, such as screwdrivers or wires.
This protection offers an additional safety guarantee, in addition
to that already provided by the spring-loaded cover assembled
on the mobile sockets.

Connector tube protective shutter for greater safety
against direct contacts. (The SAFE-IN safety device).
TRASMISSION SYSTEMS
STAND ALONE
The charging stations are not connected one to the other and
work independently. The charging stations administrator can
leave them in free charging mode (FREE) or limited to
authorized users (PERSONAL). Through the card programmer,
the administration can nevertheless influence the charging
operation depending on a specific time or number of accesses.

ACTIVE CARD
Each User Card can be programmed by assigning it an expiry
date and/or a limited number of accesses through the
208.PROG programmer, to be connected to one’s computer,
and the SLActive software supplied with the User Card.
NET
The stations are connected one to the other to a local server
whose access is assigned exclusively to the stations
administrator. In addition to being a data concentrator, the
server also contains the standard software developed in
cooperation with our standard partner GENERALE SISTEMI;
this software makes it possible to manage users, monitor and
configure the stations, calculate the consumptions, etc.
Through the card programmer, the administration can
nevertheless influence the charging operation depending on a
specific time or number of accesses.
The services are managed through a local server positioned
near the columns.

The management system of SCAME stations does not required
the installation of any software for its operation as the program
is already stored on the server.
The web page provided here below displays in real time the
operating status of the plugs of the connected stations.
REFERENCE STANDARDS
|
CEI 64-8/7
Impianti elettrici utilizzatori a tensione nominale non superiore a 1000 V in corrente alternata e a 1500 V in corrente continua Parte 7: Ambienti ed applicazioni particolari |
|
IEC 60364-7-709
Low-voltage electrical installations Part 7-709: Requirements for special installations or locations - Marinas and similar locations |
|
IEC 60364-7-711
Electrical installations of buildings Part 7-711: Requirements for special installations or locations - Exhibitions, shows and stands |
|
IEC 60364-7-740
Electrical installations of buildings Part 7-740: Requirements for special installations or locations - Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses. |
|
CEI EN 61439-1
Apparecchiature assiemate di protezione e di manovra per bassa tensione (quadri BT) Parte 1: Regole Generali |
|
CEI EN 61439-7
Apparecchiature assiemate di protezione e di manovra per bassa tensione (quadri BT) Parte 7: Quadri per installazioni pubbliche particolari quali moli, campeggi, mercati e applicazioni similari e per le stazioni di ricarica dei veicoli elettrici |
|
TECHNICAL DATA SHEET
|
| Protection degree (plastic) |
IP56 |
|
| Protection degree (metal) |
IP66 |
|
| Operating temperature according to the reference standard |
-25°C +40°C |
|
| Maximum operating temperature |
60°C |
|
| Material |
Thermoplastic |
|
| Material |
Zinc-plated metal sheet |
|
| Material |
Stainless steel (AISI 316L) |
|
| Impact resistance: IK degree at 20°C |
IK10 |
|
| Total insulation |
Yes (Class II) |
|
| Colour (plastic) |
Blue - Green - Yellow - Red - White (No RAL reference) |
|
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
|
| Saline solution |
Resistant
|
|
| Acids |
Concentrated |
Limited resistance
|
| Diluted |
Resistant
|
|
| Bases |
Concentrated |
Resistant
|
| Diluted |
Resistant
|
|
| Solvents |
Hexane |
Not resistant
|
| Benzol |
Not resistant
|
| Acetone |
Not resistant
|
| Alcohol |
Limited resistance
|
|
| Mineral oil |
Resistant
|
|
| UV rays |
Resistant
|
|
InfoTECH SERIES TECHNICAL SHEETS
| Reference |
Description |
Language |
Size |
Download |
| ZP01000-GB-1 |
KIOSK Series
Distribution pedestals terminals |
English |
411 kb
|
 |
|
All series technical sheets
VIDEO & MULTIMEDIA

KIOSK Series Distribution pedestals terminals for campsites, public areas and marinas |
|
| 60'' | KIO-GB-1 | EN | |
|
All video
MONOTHEMATIC PUBLICATIONS
| Ref. |
Description |
Language |
Size |
Download |
| ZP00873-GB-1 |
KIOSK Series
Distribution pedestals terminals for campsites, public areas and marinas
|
English |
2,94 Mb
|
  |
|
All monothematic publications
|