SERIES DETAILS
ADVANCE-GRP Series
Switched interlocked socket outlets [GRP - Glass Reinforced Polyester]

GENERAL DESCRIPTION
ADVANCE GRP 125A Switched Interlocked socket outlets are available in the following versions:
VERSIONS WITH MECHANICAL INTERLOCK
With switch-disconnector
With switch-disconnector and fuse
With fuse and switch-disconnector
With molded case circuit breaker with thermal magnetic trip unit
With molded case circuit breaker with thermal magnetic and residual current release trip units
VERSIONS WITH ELECTRICAL INTERLOCK
With contactor
PRODUCTS FOR USE IN A POTENTIALY EXPLOSIVE ENVIRONMENT
| Scame offers products suitable for installation into
environments under potential risk of explosion identified as
Zone 22 and that enter into the field of application for the
ATEX Directive (European Directive 94/9/CE).
|
|

|
TECHNICAL CHARACTERISTICS
Rated current: 125A
Rated voltage: 100&pide;690V~
Frequency: 50&pide;60Hz
Insulating voltage: 500/690V~
Protection degree: IP66
Operating temperature
according to the
reference standard: -25°C+40°C
Max. operating
temperature: 60°C
Self-extinguishing GW test: 850°C/960°C
Self-extinguishing UL94: V0
Material: Thermoset
IK degree at 20°C: IK10
Cable inlets: Top side max 2xM63
Bottom side max 2xM63
Switch-disconnectors: ABB OT 160
Fuse: NH00
Thermal magnetic protection: Molded case circuit breaker
ABB Tmax T1B (16kA) with
thermal magnetic trip unit
TMD (adjustable thermal
threshold 0,7…1 x In fixed
magnetic threshold 10 x In)
Thermal magnetic protection: Molded case circuit breaker
ABB Tmax T1B (16kA) with
thermal magnetic trip unit
TMD (adjustable thermal
threshold 0,7…1 x In fixed
magnetic threshold 10 x In) +
residual current release trip
units RC221/1 (adjustable
residual current trip 0,03 - 0,1
- 3A and time limit for non-trip
instantaneous)
Version with contactor: Contactor GE POWER
CONTROL CL09
Colour: Grey RAL7037
EX CLASSIFICATION
Atex Code: II 3D
Ex Protection type: Ex tD A22 IP66 T90°C
Operating Temperature
Range: -25°C +60°C
Maximum permissible
surface temperature: T90°C
Switched socket outlets with
interlock degree of Protection: IP66
Plugs - degree of Protection: IP66/IP67
Impact Resistance: 7J
Switched socket outlets with
interlock material: Thermoset
Plugs material: Thermoplastic
Interlocked switch sockets
outlets CE certificate: SCAME ATEX 02
Plugs CE certificate: SCAME ATEX 03
PARTICULARITIES

1 - Ample space for easy wiring
2 - Switchdisconnector with mechanical lock that can be accessorized with auxiliary contacts
3 - Punched marks for easy closure of the cover
4 - Outdoor wall fastening
5 - Under-plate cable runway
6 - Threaded metal inserts
7 - Easily extractable bottom plate
8 - Possibility to assemble microswitch

9 - Single-piece waterproof gasket
10 - Double mechanical lock and metal levers
11 - Rating on metal plate
12 - Captive stainless steel closing screws
13 - Lockable Switch in position 0 and 1
14 - High-strength material with superior UV and chemical resistance
15 - Cover entirely separate from the base for easy installation
16 - Residual current release trip units test push button
17 - An electronic device controls the status of the interlocked socket, monitoring the electrical functionality:
- operation of the signalling and control card is guaranteed even when the load is not connected;
- indicates that the fuses are not open and all the phases are present (indicator light on);
- indicates that the socket outlet is powered correctly (indicator light on);
- signals the interruption of one or more fuses (indicator light flashing);
- signals the absence of a phase (indicator light flashing)*;
- indicates that the socket outlet is not powered (indicator light off).
* for single-phase products in the event of phase/ neutral loss LED signaling appears off.

18 - Module in hightemperature glassfibre filled engineering polymer
19 - Possible entry from bottom side (input-output also)
20 - Self-centering punch marks to facilitate drilling
APPLICATION EXAMPLES
Construction sites

Big industries

Shipyards

REFERENCE STANDARDS
|
EN 60309-1
Plugs, socket outlets and couples for industrial purposes Part 1: General requirements. |
|
EN 60309-2
Plugs, socket outlets and couples for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations. |
|
EN 60309-4
Plugs, socket-outlets and couplers for industrial purposes. Part 4: Switched socket-outlets and connectors with or without interlock. |
|
TECHNICAL DATA SHEET
|
| Rated current |
16A-32A-63A-125A |
|
| Rated voltage |
100÷690V~ |
|
| Frequency |
50÷60Hz |
|
| Insulating voltage |
500/690V~ |
|
| Protection degree |
IP66/IP67/IP69 (16A-32A-63A) |
|
| Protection degree |
IP66 (125A) |
|
| Operating temperature according to the reference standard |
-25°C +60°C |
|
| Minimum operating temperature |
-40°C |
|
| Maximum permissible surface temperature |
+60°C |
|
| Self-extinguishing GW test |
960°C |
|
| Self-extinguishing UL94 |
V0 |
|
| Switched socket outlets with interlock material |
Thermosetting (GRP) |
|
| Impact resistance: IK degree at 20°C |
IK10 (20J) |
|
| Total insulation |
Yes (Class II) |
|
| Switch-disconnectors 16A-32A-63A |
COMMAND Series |
|
| Switch-disconnectors 125A |
Switch ABB OT 160 |
|
| Thermal magnetic protection 125A |
Molded case circuit breaker ABB Tmax T1B (16kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7…1 x In fixed magnetic threshold 10 x In) |
|
| Thermal-magnetic and residual current protection 125A |
Molded case circuit breaker ABB Tmax T1B (16kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7…1 x In fixed magnetic threshold 10 x In) + residual current release trip units RC221/1 (adjustable residual current trip 0,03 - 0,1 - 3A |
|
| Version with contactor 125A |
Contactor CL09 GE POWER CONTROL |
|
| Fuse: 16A-32A |
gG 10,3x38mm |
|
| Fuse: 63A |
gG 22x58mm |
|
| Fuse: 125A |
NH00 |
|
| Colour |
Grey RAL7037 |
|
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
|
| Saline solution |
Resistant
|
|
| Acids |
Concentrated |
Limited resistance
|
| Diluted |
Resistant
|
|
| Bases |
Concentrated |
Limited resistance
|
| Diluted |
Resistant
|
|
| Solvents |
Hexane |
Resistant
|
| Benzol |
Resistant
|
| Acetone |
Resistant
|
| Alcohol |
Resistant
|
|
| Mineral oil |
Resistant
|
|
| UV rays |
Resistant
|
|
InfoTECH SERIES TECHNICAL SHEETS
| Reference |
Description |
Language |
Size |
Download |
| ZP00960-GB-1 |
ADVANCE-GRP[EX] Series
Interlocked-switch socket outlets for industrial applications [ATEX] See specific catalogue [ATEX] |
English |
|
 |
|
| ZP00960-GB-1 |
ADVANCE-GRP[GD] Series
Interlocked-switch socket outlets for industrial applications [ATEX] See specific catalogue [ATEX] |
English |
|
 |
|
All series technical sheets
NEWS
All news
VIDEO & MULTIMEDIA
All video
MONOTHEMATIC PUBLICATIONS
| Ref. |
Description |
Language |
Size |
Download |
| ZP00921-GB-1 |
ADVANCE-GRP[EX] Series + OPTIMA-EX Series
Plug and socket for applications in potentially explosive atmospheres - DUST ATEX [II 2D]
|
English |
3,01 Mb
|
  |
|
All monothematic publications
|